Product Description
Technical Specifications
DC Output
A : 0-30 V, 2 A, continuously variable by means of Coarse and Fine controls
B : 5 V, 2 A adjustable from 4 V – 6 V
C:0 – ±15 V, 1 A Dual Tracking adjustable
Current Limit
100 mA – 2 A continuously adjustable for (0-30 V & 5 V)
100 mA – 1 A continuously adjustable for (± 15 V)
Resolution
Voltage : 100 mV, Current : 10 mA
Internal Resistance
£15 m
Stability
2.5 mV at (30 V / 2A, 5 V / 2 A, ±15 V / 1 A)
Recovery Time
£50 μs
Load Regulation
± (0.05 %+100 mV)
Line Regulation
± (0.05 %+100 mV)
Temp. Coefficient
± (0.05 % + 5 mV / °C)
Ripple & Noise
£1 mVrms
Display
3 digit for voltage & 3 digit for current LED indication for voltage & current
Accuracy
± (1% +1 digit)
Tracking Error
± (0.1% + 5 mV) for ± 15 V
Over Range Indication +
Glowing ‘ORA’ or ‘ORB’, ‘ORC ‘ or ‘ORC ‘LEDs indicate Overload
All outputs are floating.
Built-in overheat, Over voltage & Short Circuit protections
Insulation
Between Chassis & output terminals >10 M at 100 V DC
Between Chassis & AC plug > 50 MWat 500 V DC
Power Supply : 230 VAC